Your Position: Home > Technical Data > Valve Accessories

The electro-pneumatic converter receives the 4~20mA DC signal given by the DCS and then proportionally converts and outputs a 20~100kpa pneumatic signal, which serves as the pneumatic control signal for pneumatic diaphragm control valves and pneumatic valve positioners and as the air supply for other pneumatic instruments; it performs the signal conversion between electric instruments and pneumatic instruments.


Nozzle-flap Intelligent Positioner

This type of valve positioner is also a valve positioner with the HART communication protocol, and consists of three parts: a microprocessor-controlled electronic module, including the HART communication module and the local user interface switches; an electro-pneumatic converter based on the nozzle-flap principle; and a valve position sensor.


The working principle is that the control signal from the controller enters the printed circuit board sub-module through the terminal box, where it is read by the microprocessor, processed by a digital algorithm and converted into an analog quantity which is then sent to the I/P converter. When the signal changes, the magnetic attraction between the coil and the armature of the I/P converter changes, thereby changing the distance between the nozzle and the baffle and hence the nozzle back pressure; this back pressure, after amplification by the amplifier, is sent to the actuator and changes the valve stem position through the actuator. The valve travel sensor senses the change of the valve stem position through the feedback lever and feeds this signal back to the printed circuit board assembly for calculation. When the valve stem reaches the correct position, the valve stem position signal is fed back to the printed circuit board assembly and, after processing, stabilizes the I/P drive signal, so the nozzle back pressure stabilizes, the output force to the actuator also stabilizes and the valve stem position no longer changes.

Piezo-type Intelligent Positioner

This type of valve positioner is also a valve positioner with the HART communication protocol, and consists of three parts: a microprocessor-controlled electronic module, including the HART communication module and the local user interface switches; a piezo valve of the electro-pneumatic converter module; and a valve position sensor. For a heteropolar crystal with no center of symmetry in its crystal structure, a tensile, compressive or shear stress applied to the crystal not only produces the corresponding deformation but also induces dielectric polarization or an electric field in the crystal. This phenomenon is called the direct piezoelectric effect; conversely, if an electric field is applied to such a crystal so that the crystal becomes polarized, the crystal will also simultaneously exhibit strain or stress, which is the converse piezoelectric effect. Both are collectively called the piezoelectric effect. In 1880 the Curie brothers discovered the piezoelectric effect of tourmaline, and from then on the history of piezoelectricity began. The piezo-type pneumatic directional valve was developed by making use of the converse piezoelectric effect. The deformation of a piezoelectric material is proportional to the strength of the electric field applied to it; using this feature, proportional pressure regulating valves can be developed. As shown in figure 3, by applying different control voltages to the piezo valve plate, the piezo valve plate produces different bending deformations, thus forming different flow resistances between inlet port 1 and output port 2 and between output port 2 and exhaust port 3, so that different gas pressures are obtained at output port 2. Because the piezo valve plate is not subject to mechanical friction during deformation and has the characteristics of fast response and low power consumption, electro-pneumatic proportional pressure regulating valves based on piezo valve plates outperform conventional proportional pressure regulating valves in many respects. For example, they have no dead band and the pressure can be adjusted continuously from zero; their response is fast enough to meet the application requirements of high-speed systems; and their power consumption is low, so the requirements on power supply capacity are low.



The whole control loop is controlled by a two-wire, 4~20mA signal. The HART module sends out and receives digital information superimposed on the 4~20mA signal, realizing two-way digital communication with the microprocessor. The analog 4~20mA signal is transmitted to the microprocessor and compared with the feedback from the valve position sensor; the microprocessor performs control calculation according to the magnitude and direction of the deviation (primary control) and issues an electrical control command to the piezo valve so that it opens or closes. In the piezo valve, the width of the control command pulse corresponds to the increment of the output pressure of the pneumatic amplifier, and at the same time the output of the pneumatic amplifier is fed back to the inner control loop and compared again with the calculation result of the microprocessor (secondary control); through the two-stage control the signal is output to the actuator, and the change of the air pressure inside the actuator controls the valve travel. When the control deviation is very large, the piezo valve issues a wide pulse signal, so that the positioner outputs a continuous signal and changes the signal pressure to the actuator by a large amount to drive the valve to act quickly; as the valve approaches the required position, the difference between the commanded position and the measured position becomes smaller, and the piezo valve outputs a pulse signal of smaller width, changing the signal pressure to the actuator intermittently and by small amounts, so that the actuator moves gently towards the new commanded position. When the valve reaches the required position (enters the dead band), the piezo valve has no pulse output and the positioner output remains at zero, keeping the valve stable at a certain position. Through the local user interface setting switches, basic settings of the positioner such as gain, direct/reverse action, positioner characteristics and whether automatic calibration is permitted can be completed; without additional tools, the positioner can be calibrated automatically or manually; and through the manual control button on the local user interface, the control valve can be controlled manually.

Spool Valve Type Intelligent Positioner

(to be supplemented)

Additional functions of positioners:

Valve position feedback function: with a 4-20mA feedback signal
Diagnostic function: for example the FISHER DVC6000PD version
Three-loss position hold function: for example ABB, Siemens and YTC2500 all have this function; it is generally used in power plants.

CONTACT US

WhatsApp: +8613601902545
Wechat: 13601902545
Phone: +8613601902545
Email: wevalve@outlook.com