Your Position: Home > Technical Data > Actuators

    Pneumatic actuators



    Single-acting linear pneumatic actuator



    Direct-acting spring-diaphragm actuator and reverse-acting spring-diaphragm actuator



    Cylinder-type actuator



    Rack and pinion type



    Scotch yoke actuator

    Electric actuators

    Stroke: divided into multi-turn, part-turn and linear, 3 types.

    Multi-turn electric actuator (rotation angle >360 degrees); used to drive gate valves, globe valves, throttling valves, diaphragm valves and other linear-stroke valves whose stems move by screw motion.

    Part-turn electric actuator (rotation angle <360 degrees); the rotation of the output shaft of the electric actuator is less than one revolution, i.e. less than 360 degrees, and usually 90 degrees is used to realize the opening and closing control of the valve.
    This type of electric actuator is further divided into the direct-coupled type and the base crank type according to the different mounting interface.
    a) Direct-coupled type: refers to the form in which the output shaft of the electric actuator is mounted directly to the valve stem.
    b) Base crank type: refers to the form in which the output shaft is connected to the valve stem through a crank. This type of electric actuator is suitable for butterfly valves, ball valves and plug valves.

    Linear-stroke electric actuator used to drive single-seat valves, cage valves and other linear-stroke valves whose stems move in a straight line, as shown on the right side of the figure above. A linear-stroke intelligent electric actuator can be realized by combining a multi-turn intelligent electric actuator with a linear thruster.

    Function:

    Divided into two major categories: on/off type (open-loop control) and modulating type (closed-loop control).

    1. On/off type (open-loop control)--an on/off electric actuator generally realizes the open or close control of the valve; the valve is either in the fully open position or in the fully closed position, and this type of valve does not require precise control of the medium flow. It is particularly worth mentioning that on/off electric actuators can also be divided into split structure and integrated structure according to their structural form. This must be stated when selecting a model, otherwise it often happens that the actuator conflicts with the control system and does not match during on-site installation.
    -a) Split structure (usually called the ordinary type): the control unit is separate from the electric actuator; the electric actuator cannot realize valve control on its own and must be provided with an additional control unit to achieve control, usually in the form of an external controller or control cabinet. The disadvantage of this structure is that it is inconvenient for the overall installation of the system, the level transmitter increases wiring and installation costs, and faults occur easily; when a fault occurs it is not easy to diagnose and repair, so the cost-effectiveness is not ideal.
    -b) Integrated structure (usually called the integral type): the control unit and the electric actuator are packaged as one unit, so local operation is possible without an external control unit, and remote operation only requires outputting the relevant control information. The advantages of this structure are that it facilitates the overall installation of the system, reduces wiring and installation costs, and makes it easy to diagnose and eliminate faults. However, conventional integrated-structure products also have many imperfections, so intelligent electric actuators came into being; intelligent electric actuators will be described later.

    2. Modulating type (closed-loop control)--a modulating electric actuator not only has the function of an on/off integrated structure and precise regulation of the medium flow, but can also control the valve precisely.

    -a) Type of control signal (current, voltage); the control signal of a modulating electric actuator is generally a current signal (4~20mA, 0~10mA) or a voltage signal (0~5V, 1~5V); the type and parameters of the control signal must be specified when selecting a model.
    -b) Working mode (electrically open, electrically closed); the working mode of a modulating electric actuator is generally the electrically open type (taking 4~20mA control as an example, electrically open means that a 4mA signal corresponds to the valve closed and 20mA corresponds to the valve open), and the other is the electrically closed type (taking 4-20mA control as an example, electrically open means that a 4mA signal corresponds to the valve open and 20mA corresponds to the valve closed). Generally the working mode must be specified when selecting a model, and many products cannot be modified after leaving the factory; the intelligent electric actuators produced by Aomei Valve Control can be modified at any time by on-site setting.
    -c) Fail-safe on loss of signal; fail-safe on loss of signal means that when the control signal is lost due to a line fault or other fault, the electric actuator will drive the valve to the set protection position; the common protection positions are fully open, fully closed and stay in place, three cases.

     

    Selection points:

    Linear- or quarter-turn actuator Linear or quarter-turn stroke

    Nominal current [VAC] / [VDC] Voltage: 24VDC/220VAC

    Max. thrust [kN]/Max. torque [Nm] Maximum thrust or maximum torque requirement

    Modulating or 3-point Modulating or 3-point

    Failsafe(Yes/No) Fail-safe position on power loss (yes/no)

    1. Select the valve electric actuator according to the valve operating torque: the torque required for normal opening and closing of the valve is determined by factors such as the valve nominal size and working pressure, but because valve manufacturers differ in machining accuracy and assembly process, valves of the same specification produced by different manufacturers also require different torques, and even valves of the same specification produced by the same manufacturer differ in torque. If the torque chosen for the actuator is too small during selection, the valve cannot be opened and closed normally; therefore a reasonable torque range must be chosen for the electric actuator. The output torque of the electric actuator should be 1.2~1.5 times the maximum operating torque of the valve.

    2. Determine the electrical parameters according to the electric actuator: because the electrical parameters of different actuator manufacturers differ, the electrical parameters generally have to be determined during design and selection, mainly motor power, rated current, secondary control circuit voltage, etc. Negligence in this respect often results in a mismatch between the control system and the electric actuator parameters, causing faults such as no-load tripping, fuse blowing and thermal overload relay protection tripping during operation.

    3. Operating thrust The main unit structure of the valve electric device has two forms: one is without a thrust plate, outputting torque directly; the other is with a thrust plate, where the output torque is converted into output thrust through the stem nut in the thrust plate.

    4. Number of output shaft revolutions The number of revolutions of the output shaft of the valve electric device is related to the nominal diameter of the valve, the stem thread pitch and the number of thread starts, and must be calculated according to M=H/ZS (M is the total number of revolutions the electric device should provide, H is the valve opening height, S is the thread pitch of the stem drive thread, and Z is the number of stem thread starts).

    5. Stem diameter For multi-turn rising-stem valves, if the maximum stem diameter that the electric device allows to pass cannot accommodate the stem of the matched valve, it cannot be assembled into an electric valve. Therefore the inner diameter of the hollow output shaft of the electric device must be greater than the outer diameter of the stem of the rising-stem valve. For part-turn valves and non-rising-stem valves among multi-turn valves, although the passage of the stem diameter does not have to be considered, the dimensions of the stem diameter and the keyway should still be fully considered when matching, so that it works properly after assembly.

    6. Output speed If the opening and closing speed of the valve is too fast, water hammer is likely to occur. Therefore an appropriate opening and closing speed should be selected according to the different service conditions.

    7. Valve electric actuators have their special requirements, namely they must be able to limit the torque or axial force. Usually the valve electric device adopts a torque-limiting coupling. Once the specification of the electric device is determined, its control torque is also determined. Generally, when operating within a predetermined time, the motor will not be overloaded.
    But the following situations may lead to overload:
    First, the supply voltage is low and the required torque cannot be obtained, so the motor stops rotating;
    Second, the torque limiting mechanism is incorrectly set so that it is greater than the stopping torque, causing continuous excessive torque and stopping the motor;
    Third, intermittent use causes heat to accumulate and exceed the allowable temperature rise of the motor;
    Fourth, for some reason the circuit of the torque limiting mechanism fails, making the torque excessive; fifth, the ambient temperature is too high, which relatively reduces the thermal capacity of the motor.

    In the past, the methods used to protect the motor were fuses, overcurrent relays, thermal relays, thermostats, etc., but these methods each have advantages and disadvantages. For a variable-load device such as an electric device there is no absolutely reliable protection method. Therefore various combinations must be adopted, which can be summarized in two ways:
    one is to judge the increase or decrease of the motor input current;
    the other is to judge the heating condition of the motor itself.
    Either way, the time margin given by the thermal capacity of the motor must be taken into account. Usually the basic overload protection methods are:
    1. For overload protection of continuous operation or inching operation of the motor, a thermostat is used;
    2. For protection against motor stalling, a thermal relay is used;
    3. For short-circuit accidents, a fuse or overcurrent relay is used.