Location: Home > Technical Data > Self-Operated Regulating Valve
A self-operated control valve needs no external power source; it operates by itself using only the energy of the controlled fluid and keeps the controlled variable constant.
1. By function, self-operated pressure regulating valves are divided into upstream pressure regulation, downstream pressure regulation and differential pressure regulation.
Upstream pressure regulation regulates the pressure upstream of the valve and is also called a pressure relief valve, with the pressure tapping point upstream of the valve; downstream pressure regulation has its pressure tapping point downstream of the valve and is also called a pressure reducing valve. A differential pressure self-operated valve is used to keep constant the pressure difference between the inlet and outlet of a device or a circuit connected in series with it. When the pressure difference of the controlled object is greater than the set value, the valve closes down; when the pressure difference of the controlled object is less than the set value, the valve opens wider. The pressure drop across the valve itself changes with the available head of the external network, so as to keep the pressure difference of the controlled object constant.
2. By structure, self-operated regulating valves are further divided into direct-acting and indirect-acting types.
Direct-acting regulating valve, also called spring-loaded regulating valve, contains elastic elements in its structure, such as springs, bellows and bellows-type temperature bulbs, and works on the principle of balancing the elastic force against the feedback signal.
2) Indirect-acting regulating valve: a pilot valve (pilot) is added, which amplifies the feedback signal, and then through the actuator it drives the main valve disc to change the valve opening.
Nitrogen Blanketing Valve
A type of self-operated pressure reducing valve, characterized by a slight positive pressure (mbar) downstream of the valve.