    Working principle of solenoid valves A solenoid valve is composed of an electromagnetic coil and a magnetic core, and is a valve body containing one or several ports. When the coil is energized or de-energized, the movement of the magnetic core causes the fluid to pass through the valve body or to be shut off, so as to change the direction of the fluid. The electromagnetic part of a solenoid valve is composed of a fixed iron core, a movable iron core, a coil and other parts; the valve body part is composed of a spool, a spool sleeve, a spring seat and other parts. The electromagnetic coil is mounted directly on the valve body, and the valve body is enclosed in a sealing tube, forming a simple and compact assembly.

    Solenoid valves are divided into three main categories in principle (namely: direct-acting, semi-direct-acting and pilot-operated). In terms of the gas circuit or oil circuit, the solenoid valves commonly used in our production are two-position three-way, two-position four-way, two-position five-way, etc. The “two-position” of a solenoid valve means that the spool of the solenoid valve has two different working positions (open and closed). And “how many ways” means how many port openings there are on the valve body of the solenoid valve; for example, a two-position two-way solenoid valve has one inlet and one outlet (two passages, the most common type); a two-position three-way solenoid valve controls liquid with one inlet and two outlets (the two outlets being respectively one normally open and one normally closed); a pneumatic directional solenoid valve has one inlet, one outlet and one exhaust; a hydraulic one has one inlet, one outlet and one return oil port.

    Solenoid valves are divided into three main categories by structural principle:

    1) Direct-acting solenoid valve:
    Principle: when energized, the electromagnetic coil generates electromagnetic force that lifts the closing member off the valve seat and the valve opens; when de-energized, the electromagnetic force disappears and the spring presses the closing member onto the valve seat and the valve closes.
    Features: it can work normally under vacuum, negative pressure and zero pressure, but the bore generally does not exceed 25mm.

    2) Semi-direct-acting solenoid valve:
    Principle: this is a principle combining direct-acting and pilot-operated. When there is no pressure difference between inlet and outlet, after energizing, the electromagnetic force directly lifts the small pilot valve and the main valve closing member in turn, and the valve opens. When the pressure difference between inlet and outlet reaches the starting value, after energizing, the electromagnetic force acts on the small pilot valve, the pressure in the lower chamber of the main valve rises and the pressure in the upper chamber drops, so that the pressure difference pushes the main valve upward; when de-energized, the pilot valve uses spring force or medium pressure to push the closing member downward and close the valve.
    Features: it can also act at zero pressure difference, vacuum or high pressure, but the power is relatively large and horizontal installation is required.
    3) Pilot-operated solenoid valve:
    Principle: when energized, the electromagnetic force opens the pilot orifice, the pressure in the upper chamber drops rapidly, and a pressure difference with low pressure above and high pressure below is formed around the closing member; the fluid pressure pushes the closing member upward and the valve opens; when de-energized, the spring force closes the pilot orifice, the inlet pressure quickly enters the chamber through the bypass orifice and forms a pressure difference with low pressure below and high pressure above around the closing member; the fluid pressure pushes the closing member downward and closes the valve.
    Features: the upper limit of the fluid pressure range is relatively high and it can be installed in any position (customized required), but the fluid pressure difference conditions must be met.

    Solenoid valves classified by flow path

    Two-position three-way solenoid valve:

    In terms of the gas circuit (or liquid circuit), a two-position three-way solenoid valve has 1 air inlet (connected to the air supply), 1 air outlet (supplying air to the target equipment) and 1 exhaust port (generally a silencer is installed; if noise is not a concern, it may be left uninstalled). Electrically, a two-position three-way solenoid valve is generally single-solenoid (that is, single coil). Two-position three-way solenoid valves are divided into normally closed and normally open types. Normally closed means the air circuit is cut off when the coil is not energized; normally open means the air circuit is connected when the coil is not energized. Operating principle of the normally closed two-position three-way solenoid valve: energize the coil and the air circuit is connected; once the coil is de-energized the air circuit is cut off, which is equivalent to “jogging”. Operating principle of the normally open two-position three-way single-solenoid solenoid valve: energize the coil and the air circuit is cut off; once the coil is de-energized the air circuit is connected, which is also “jogging”.



    Figure 1 shows a simple sectional view and the working principle of the structure of a two-position three-way direct-acting solenoid valve (normally closed type). When the coil is energized, the fixed iron core generates electromagnetic force, the spool moves upward under the action of the electromagnetic force, the sealing pad is lifted, ports 1 and 2 are connected and ports 2 and 3 are cut off, the valve is in the air-intake state and can control the action of the cylinder. When de-energized, the spool returns to its original position by the action of the spring force, that is, 1-2 are cut off and 2-3 are connected, and the valve is in the exhaust state.
    Two-position five-way solenoid valve
    A two-position five-way solenoid valve has 1 air inlet (connected to the air supply), 1 forward-action air outlet and 1 reverse-action air outlet (respectively supplying the forward and reverse action air supplies to the target equipment), 1 forward-action exhaust port and 1 reverse-action exhaust port (with silencers installed). A two-position five-way solenoid valve is generally double-solenoid (that is, double coil). Operating principle of the two-position five-way double-solenoid solenoid valve: energize the forward-action coil, then the forward-action air circuit is connected (there is air at the forward-action outlet); even after the forward-action coil is de-energized the forward-action air circuit remains connected, and this will be maintained until the reverse-action coil is energized. Energize the reverse-action coil, then the reverse-action air circuit is connected (there is air at the reverse-action outlet); even after the reverse-action coil is de-energized the reverse-action air circuit remains connected, and this will be maintained until the forward-action coil is energized. This is equivalent to “self-locking”.
    Figure 2 shows a simple sectional view and the working principle of the structure of a two-position five-way direct-acting solenoid valve (normally closed type). In the initial state, 1-2 intake, 4-5 exhaust; when the coil is energized, the fixed iron core generates electromagnetic force that actuates the pilot valve, compressed air enters the pilot piston of the valve through the air circuit and starts the piston; in the middle of the piston the sealing circular face opens the passage, 1-4 intake, 2-3 exhaust; when de-energized, the spool returns to its original position by the action of spring force.
    Other solenoid valves with different numbers of positions and ways

    Two-position two-way solenoid valve:

    When the left electromagnetic coil is energized, the iron core overcomes the spring force on the right and other related resistances and pushes the piston, so that the flow passage from P to A is connected. When the left electromagnetic coil is de-energized, the right spring overcomes the gas resistance and other related resistances and pushes the piston, so that the flow passage from P to A is cut off.

    Two-position four-way solenoid valve:
    When the left electromagnetic coil is energized, the iron core overcomes the spring force on the right and other related resistances and pushes the piston; the passage from P to A is connected and the passage from O to B is connected, and the valve push rod moves to the right under the action of the pressure difference. When the left electromagnetic coil is de-energized, the iron core overcomes the gas pressure and other related resistances and pushes the piston, and the piston returns under the action of the spring; the passage from P to B is connected and the passage from O to A is connected, and the valve push rod moves to the left under the action of the pressure difference.

    Three-position three-way solenoid valve:
    When the left electromagnetic coil is energized, the iron core overcomes the spring force on the right and other related resistances and pushes the piston; the passage from A to P is connected and compressed air flows normally, while the passage from A to O is blocked. When the right electromagnetic coil is energized, the iron core overcomes the spring force on the right and other related resistances and pushes the piston; the passage from A to O is connected and the passage from A to P is blocked. When both the left and right coils are de-energized, the springs at both ends push the piston to stay in the middle position, maintaining the reset state and blocking the inlet A.

    Three-position four-way solenoid valve:
    When the left electromagnetic coil is energized, the iron core pushes the piston; the passage from A to P is connected and B to O is connected. When the right electromagnetic coil is energized, the iron core pushes the piston; the passage from B to P is connected and A to O is connected. When both the left and right coils are de-energized, the piston returns under the action of the springs and blocks all passages.

    Three-position five-way solenoid valve:
    When the left coil is energized, the passage from P to B is connected, the right side of the cylinder takes in air and the pressure increases, while A to R is connected, the left side exhausts and the pressure decreases, and the cylinder piston moves to the left. When the right coil is energized, the passage from P to A is connected, the left side of the cylinder takes in air and the pressure increases, while B to S is connected, the right side exhausts and the pressure decreases, and the cylinder piston moves to the right. When both coils are de-energized, the piston returns under the action of the springs and blocks all passages, and the cylinder piston remains in its current state.

    Sizing requirements for solenoid valves:
    Solenoid valves for gas circuits:
    Number of positions and ways / direct-acting or pilot-operated / body material of the air passage / material of the coil junction box / bore / air supply pressure / power consumption / voltage / electrical interface / explosion protection grade and protection grade: the explosion protection grade mainly is: flameproof? intrinsically safe? increased safety? or non-explosion-proof (waterproof and dustproof only) / mounting method: pipe-mounted (threaded)? or plate-mounted (NAMUR)?
    Solenoid valves for process:
    Number of positions and ways / nominal bore / flange connection or threaded connection / medium name and corrosiveness / temperature and pressure rating / sealing class / explosion protection grade (such as ExidIIBT4) and protection grade (such as IP65) / power requirement (such as less than 30W) / electrical interface (such as 1/2NPT), manual reset device included or not?
    Points to note when sizing solenoid valves
    One: Applicability The fluid in the pipeline must be consistent with the medium rated in the selected solenoid valve series model. The temperature of the fluid must be lower than the rated temperature of the selected solenoid valve. The liquid viscosity allowed by a solenoid valve is generally below 20CST; if it is greater than 20CST this should be noted. Working pressure difference: when the maximum pressure difference in the pipeline is less than 0.04MPa, direct-acting and semi-direct-acting types such as the ZS, 2W, ZQDF and ZCM series should be selected; when the minimum working pressure difference is greater than 0.04MPa, a pilot-operated (pressure-difference) solenoid valve can be selected; the maximum working pressure difference should be less than the maximum rated pressure of the solenoid valve; generally solenoid valves work in one direction only, so attention should be paid to whether there is a reverse pressure difference, and if so a check valve should be installed. When the cleanliness of the fluid is not high, a filter should be installed upstream of the solenoid valve; generally solenoid valves require good medium cleanliness. Pay attention to the flow orifice and the connecting pipe diameter; solenoid valves generally only have two-position on/off control; where conditions permit, install a bypass pipe for ease of maintenance; when water hammer occurs, the opening and closing time of the solenoid valve must be customized and adjusted. Pay attention to the influence of ambient temperature on the solenoid valve. The supply current and power consumption should be selected according to the output capacity; the supply voltage generally allows a tolerance of about ±10%, and it must be noted that the VA value is relatively high when AC is started.
    Two: Reliability Solenoid valves are divided into normally closed and normally open types; generally the normally closed type is selected, which opens when energized and closes when de-energized; but when the open time is very long and the closed time is very short, the normally open type should be selected. Life test: in factories this generally belongs to the type test items; to be precise, China does not yet have a professional standard for solenoid valves, so be cautious when choosing a solenoid valve manufacturer. When the action time is very short and the frequency is relatively high, generally select the direct-acting type; for large bores select the quick-action series.
    Three: Safety Generally solenoid valves are not waterproof; where conditions do not permit, please select the waterproof type, which can be customized by the factory. The maximum rated nominal pressure of the solenoid valve must exceed the maximum pressure in the pipeline, otherwise the service life will be shortened or other unexpected situations will occur. For corrosive liquids the all-stainless-steel type should be selected; for strongly corrosive fluids the plastic king (SLF) solenoid valve is preferable. In explosive atmospheres the corresponding explosion-proof product must be selected.
    Four: Economy Many solenoid valves can be used interchangeably, but on the basis of satisfying the above three points the most economical product should be selected. [Edit this section] Sizing of solenoid valves When sizing a solenoid valve, the four principles of safety, reliability, applicability and economy should first be followed in order, and secondly the selection should be based on the site working conditions in six respects (namely pipeline parameters, fluid parameters, pressure parameters, electrical parameters, mode of action and special requirements).
    Basis for sizing:
    One. Select the following of the solenoid valve according to pipeline parameters: bore specification (that is DN) and connection type 1. Determine the bore (DN) size according to the actual inner diameter of the pipeline or the flow requirement. 2. Connection type: generally for >DN50 a flange connection should be selected, and for ≤DN50 it can be freely selected according to user needs.
    Two. Select the following of the solenoid valve according to fluid parameters: material and temperature group 1. Corrosive fluids: corrosion-resistant solenoid valves and all-stainless-steel types are preferable; edible ultra-clean fluids: solenoid valves of food-grade stainless steel are preferable. 2. High-temperature fluids: select solenoid valves manufactured with high-temperature-resistant electrical and sealing materials, and select the piston-type structure. 3. Fluid state: broadly gaseous, liquid or mixed; this must be distinguished especially when ordering with a bore larger than DN25. 4. Fluid viscosity: generally below 50cSt any type can be selected; if above this value, a high-viscosity solenoid valve must be selected.
    Three. Select the following of the solenoid valve according to pressure parameters: principle and structural type 1. Nominal pressure: this parameter has the same meaning as for other general valves and is determined by the nominal pressure of the pipeline. 2. Working pressure: if the working pressure is low, the direct-acting or semi-direct-acting principle must be selected; when the minimum working pressure difference is above 0.04MPa, the direct-acting, semi-direct-acting and pilot-operated types can all be selected.

    Four. Electrical selection: for voltage specification, AC220V and DC24 should be given priority as they are more convenient.
    Five. Select according to the length of continuous working time: normally closed, normally open, or continuously energizable 2. If the open time is short or the number of opening and closing operations is small, select the normally closed type. 3. However, for some working conditions used for safety protection, such as furnace and kiln flame monitoring, the normally open type must not be selected; the continuously energizable type should be selected.
    Six. Select auxiliary functions according to environmental requirements: explosion protection, non-return, manual operation, water and mist protection, water spray protection, submersible 1. Explosive atmospheres: solenoid valves of the corresponding explosion protection grade must be selected (our company currently offers: d II BT4, d II CT5, Ex m I/II T4). 2. When there is reverse flow of the fluid in the pipe, the OK71-N and OK72-N series solenoid valves with non-return function from our company can be selected. 3. When on-site manual operation of the solenoid valve is required, the OK71-S and OK72-S series solenoid valves with manual function from our company can be selected. 4. For outdoor installation or dusty locations, waterproof and dustproof types should be selected (protection grade above IP54). 5. For fountains, submersible solenoid valves must be used (protection grade above IP68). 1. When the solenoid valve needs to be open for a long time and the continuous time exceeds the closed time, the normally open type should be selected.
    Characteristics to note when selecting and using
    One. Safety: 1. Corrosive media: plastic king solenoid valves and all-stainless-steel types are preferable; for strongly corrosive media the isolated diaphragm type must be selected, for example CD-F and Z3CF. For neutral media, solenoid valves with copper alloy as the valve shell material are also preferable; otherwise rust flakes often fall off from the valve shell, especially in applications with infrequent operation. Copper material must not be used for ammonia valves. 2. Explosive atmospheres: products of the corresponding explosion protection grade must be selected; for outdoor installation or dusty locations, waterproof and dustproof types should be selected. 3. The nominal pressure of the solenoid valve should exceed the maximum working pressure in the pipe.
    Two. Applicability: 1. Medium characteristics 1.1 Gaseous, liquid or mixed states require different types of solenoid valves respectively; for example ZQDF is used for air, ZQDF—Y for liquids and ZQDF—2 (or -3) for steam, otherwise misoperation is easily caused. The ZDF series multifunctional solenoid valve can be used for gas and liquids alike. It is best to state the medium state when ordering, so that the installation user does not have to adjust it again. 1.2 The medium temperature must match the product specification, otherwise the coil will burn out and the seals will age, seriously affecting the service life. 1.3 Medium viscosity, generally below 50cSt. If above this value and the bore is larger than 15mm, use the ZDF series multifunctional solenoid valve as a special order. If the bore is smaller than 15mm, order a high-viscosity solenoid valve. 1.4 When the cleanliness of the medium is not high, a back-flushing filter valve should be installed upstream of the solenoid valve; when the pressure is low, a direct-acting diaphragm type solenoid valve such as CD—P can be selected. 1.5 If the medium flows in one direction only and reverse flow is not allowed, the ZDF—N and ZQDF—N require two-way flow; please raise this as a special requirement. 1.6 The medium temperature should be selected within the range allowed by the solenoid valve. 2. Pipeline parameters 2.1 Select the valve ports and model according to the medium flow direction requirements and the pipeline connection type. For example, for switching one pipeline to two pipelines, select CA5 and Z3F for small bores, and ZDF—Z1/2 for medium or large bores. Also, for controlling the merging of two pipelines, select ZDF—Z2/1, etc. 2.2 Determine the nominal bore according to the flow rate and the Kv value of the valve; the inner diameter of the pipeline can also be used. Please note that some manufacturers do not mark the Kv value, and often the valve orifice size is smaller than the connecting pipe diameter; do not ruin matters by seeking a low price. 2.3 Working pressure difference When the minimum working pressure difference is above 0.04MPa, the indirect pilot-operated type can be selected; when the minimum working pressure difference is close to or less than zero, the direct-acting or semi-direct-acting type must be selected. 3. Environmental conditions 3.1 The maximum and minimum ambient temperatures should be within the allowed range; if out of tolerance, a special order must be raised. 3.2 Where the ambient relative humidity is high or there are water droplets or rain, waterproof solenoid valves should be selected 3.3 Where there is frequent vibration, jolting and impact in the environment, special types should be selected, for example marine solenoid valves. 3.4 In corrosive or explosive environments, corrosion-resistant types should be selected first according to safety requirements 3.5 If the ambient space is restricted, select the multifunctional solenoid valve, because it eliminates the bypass and three manual valves and facilitates online maintenance. 4. Power supply conditions 4. 1 Select AC or DC solenoid valves respectively according to the type of power supply; generally AC power is more convenient. 4.2 For voltage specification, give priority to AC220V and DC24V. 4.3 For supply voltage fluctuation, generally +10%/-15% is selected for AC and about ±10% is allowed for DC; if out of tolerance, voltage stabilization measures must be taken or a special order requirement raised. 4.4 The rated current and power consumption should be selected according to the power supply capacity. Note that the VA value is relatively high when AC is started; when the capacity is insufficient, the indirect pilot-operated solenoid valve should be selected first. 5. Control accuracy 5.1 An ordinary solenoid valve has only two positions, open and closed; where high control accuracy is required and stable parameters are needed, please select a multi-position solenoid valve; the Z3CF three-position normally open solenoid valve has three flow rates: slightly open, fully open and closed; the ZDF-Z1/1 combined multifunctional solenoid valve has four flow rates: fully open, large open, small open and fully open. 5.2 Action time: refers to the time from the electrical signal being switched on or off to the completion of the main valve action; only our company's patented multifunctional solenoid valve can adjust the opening and closing times separately, which not only meets the control accuracy requirements but also prevents water hammer damage. 5.3 Leakage The leakage values given in the catalogue are the common economic class; if these are considered too high, please make a special order.

    Three. Reliability: 1. Working life: this item is not included in the factory test items and belongs to the type test items. To ensure quality, branded products from regular manufacturers should be selected. 2. Working duty: there are three types: continuous duty, intermittent periodic duty and short-time duty. Our company's standard products are all continuous duty, that is, the coil is allowed to work energized for a long time. For situations where the valve is open for a long time and closed only briefly, the normally open solenoid valve is preferable. Where short-time duty is used and the quantity is very large, a special order can be made to reduce power consumption. 3. Working frequency: when a high action frequency is required, the direct-acting solenoid valve should be preferred in structure and AC should be preferred for the power supply. 4. Action reliability Strictly speaking, this test has not yet been formally included in China's professional standard for solenoid valves; to ensure quality, branded products from regular manufacturers should be selected. In some applications the number of operations is not large but the reliability requirement is very high, such as fire protection and emergency protection; this must not be taken lightly. Particularly important cases should use two valves in series for double insurance.
    Four. Economy: This is one of the criteria for selection, but the economy must be on the basis of safety, applicability and reliability. Economy is not only the selling price of the product; the function and quality, as well as the costs required for installation, maintenance and other accessories, must be given priority consideration. More importantly, the cost of one solenoid valve in the entire automatic control system, and even in the production line, is negligible; if damage is caused by wrongly selecting a product in order to seek a small advantage, the loss is enormous.
    Sealing materials of solenoid valves NBR/EPDM/VITON fluororubber (FKM)
    Installation notes:
    1. During installation, note that the arrow on the valve body should be consistent with the flow direction of the medium. Do not install in places with direct dripping or splashing water. The solenoid valve should be installed vertically upward.
    2. The solenoid valve should be guaranteed to work normally within the range of 15%-10% fluctuation of the supply voltage from the rated voltage.
    3. After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It must be energized several times and allowed to reach the proper temperature before being put into formal service.
    4. The pipeline should be thoroughly cleaned before installing the solenoid valve. The medium introduced should be free of impurities. Install a filter upstream of the valve.
    5. When the solenoid valve fails or is being cleaned, a bypass device should be installed to ensure continued operation of the system.

    Applications of Solenoid Valves


    Solenoid valve: used for on/off control of liquid and gas pipelines, with two-position DO control. Generally used for the control of small pipelines.
    Solenoid valve: can only be used for on/off quantities, with DO control, and can only be used for small pipeline control, commonly in DN50 and smaller pipelines, and rarely above that.
    1. Switching form: The solenoid valve is driven through a coil and can only open or close, and the action time when switching is short.
    2. Working nature: Solenoid valves generally have a very small flow coefficient and a very small working pressure difference. For example, the flow coefficient of a solenoid valve of 25 bore is much smaller than that of an electric ball valve of 15 bore. The solenoid valve is driven through an electromagnetic coil and is relatively easily damaged by voltage surges. It is equivalent to the function of a switch, that is, the two functions of opening and closing.
    Solenoid valves generally reset when de-energized; electric valves require a reset device to have this function.

    Common faults of solenoid valves:

    ■ The solenoid valve coil burns out, generally easily caused by moisture and water ingress
    ■ The solenoid valve sticks, with impurities entering.
    ■ The solenoid valve leaks air, generally because the sealing gasket is damaged or the spool is worn
    One. The solenoid valve does not work after energizing Check whether the power supply wiring is poor→rewire and reconnect the connectors Check whether the supply voltage is within the ±working range→adjust to the normal position range Whether the coil is desoldered→resolder Whether the coil is short-circuited→replace the coil Whether the working pressure difference is unsuitable→adjust the pressure difference→or replace with a matching solenoid valve Whether the fluid temperature is too high→replace with a matching solenoid valve Whether impurities have stuck the main spool and the movable iron core of the solenoid valve→clean it; if the seal is damaged, replace the seal and install a filter Whether the liquid viscosity is too high, the frequency too high and the life has expired→replace the product
    Two. The solenoid valve cannot close The sealing elements of the main spool or the movable iron core are damaged→replace the sealing elements Whether the fluid temperature and viscosity are too high→replace with a suitable solenoid valve Whether impurities have entered the valve spool or the movable iron core of the solenoid valve→clean it Whether the spring life has expired or the spring is deformed→replace it Whether the throttling orifice and balance orifice are blocked→clean in time Whether the working frequency is too high or the life has expired→change to or replace with a new product
    Three. Other situations Internal leakage→check whether the sealing elements are damaged and whether the spring is improperly assembled External leakage→loose connections or damaged sealing elements→tighten the screws or replace the sealing elements Noise when energized→loose fasteners at the head, tighten them. Voltage fluctuation outside the allowable range, adjust the voltage properly. Impurities or unevenness on the iron core attracting surface, clean or replace in time.