Your Position: Home > Technical Data > Certifications

    Various Certifications


    ISO9001 certification)
    Quality system certification is one of a group of core standards of the quality management system covered by the ISO9000 family of standards. The ISO9000 family of standards is a concept proposed by the International Organization for Standardization (ISO) in 1994, referring to "international standards developed by ISO/TC176 (the ISO technical committee on quality management and quality assurance)."
    Example

    ISO14001 certification)
    The full name of ISO14001 certification is ISO14001 environmental management system certification, referring to the conformity assessment activity carried out by a third-party certification body in accordance with the ISO14001 standard. ISO14001 is a standard published by the International Organization for Standardization and is one of the ISO14000 family of standards; the standard was first published in 1996 and was revised by the ISO International Organization for Standardization in 2004, and the latest version is ISO14001-2004.
    Example


    PED (Pressure Equipment Directive))
    This EU directive (97/23/CE) is used to certify equipment placed on the market that must meet safety requirements. Some products are self-certified by the manufacturer (category 1), while others are certified after testing by an independent certification company.

    Example



    ACS (Sanitary Conformity Certificate)

    The sanitary conformity certificate (ACS) is an official certification issued by the French General Directorate of Health. It has been a mandatory certification since 24 December 2006. It applies to the materials of which equipment in contact with water (intended for human consumption) is made, and to the equipment itself.

    API certification
    API-6AAPI-Q1
    API is the American Petroleum Institute; an important task of API certification is to be responsible for the standardization of equipment used in the oil and natural gas industry, so as to ensure the safety, reliability and interchangeability of the equipment used in this industry.

    TUV certification
    The TüV mark is a safety certification mark customized by Germany's TüV specifically for component products, and is widely accepted in Germany and Europe. At the same time, when applying for the TüV mark an enterprise may also apply for a CB certificate at the same time, thereby obtaining certificates of other countries through conversion. Moreover, after a product has passed certification, the German TüV will recommend these products to rectifier manufacturers who inquire about qualified component suppliers; in the certification of complete machines, all components that have obtained the TüV mark can be exempted from inspection.

    OHSAS-18001 Occupational Health and Safety System Certification
    Example

    CSA Canadian Standards Association certification

    SIL
    Application of SIL Example
    SIL (Safety Integrity Level) - SIL certification is a third-party assessment, verification and certification of the safety integrity level (SIL) or performance level (PL) of safety equipment based on standards such as IEC 61508, IEC 61511, IEC 61513, IEC 13849-1, IEC 62061, IEC 61800-5-2. Functional safety certification mainly involves the assessment of the document management (FSM) of the safety equipment development process, hardware reliability calculation and assessment, software assessment, environmental testing, EMC electromagnetic compatibility testing, etc. SIL certification is divided into 4 levels, SIL1, SIL2, SIL3 and SIL4, covering both the product and the system level. SIL4 has the highest requirements, such as the ATP system of railways and the SIS system of petrochemicals and power. Petrochemical instrument products are generally SIL2 and SIL3
    SIL certification bodies include: Bureau Veritas BV, TUV Rheinland, TUV SUD, TUV NORD, Exida, SGS, ECM, the Shanghai Institute of Instrument and Automation System Inspection and Testing (SITIIAS) and the Institute of Instrumentation Comprehensive Economic Research of the Machinery Industry (ITEI).
    Bureau Veritas BV TUV

    TA-LUFT certification
    The German Technical Instructions on Air Quality Control (stem leakage protection certification); TA-LUFT is a German certification, a standard for air cleanliness, and generally requires the packing (packing set) in the stem to be of low leakage and to meet the TA-LUFT requirements.

    TSG certification
    General Administration of Quality Supervision: special equipment "pressure piping components" and "materials" manufacturing license

    EPA certification
    United States Environmental Protection Agency certification

    NSF certification
    Example

    VDE certification
    Example

    UL certification


    GOST certification
    GOST-R is the Russian certification system, certifying that the safety and quality standards of goods, products or services comply with the requirements of the Russian Federation.


    ATEX certification
    ATEX is a standard named after "ATmosphere EXplosible" (explosive atmosphere) and consists of two EU directives: the European 94/9/EC standard and the 1999/92/EC standard. 1999/92/EC is aimed at companies with potentially explosive gas atmospheres, while 94/9/EC is aimed at the instrument suppliers of the former. ATEX certification is the mandatory certification for explosion-proof electrical products in the European market; it strictly specifies the characteristics and operating rules of explosion-proof products. Since 1 July 2003, only products with ATEX certification may be produced, manufactured, sold and used in explosive hazardous areas in EU countries. That is to say, any explosion-proof product sold in EU countries and used in explosive hazardous areas must pass ATEX certification. This certification replaced the local certifications of the EU countries.
    Example


    The New European Explosion-Proof Standard ATEX

    The new European explosion-proof standard ATEX
    1.1 The "ATEX 137 (ATEX 1999/92/EC art.137) directive" standard
    The "ATEX 137 (ATEX 1999/92/EC art.137) directive" standard came into force on 28 January 2000 and became mandatory from 1 July 2003. This standard carries out a risk assessment of explosive gas and dust atmospheres and defines the concept of "zone".
    1.1.1 Explosive mixture
    An explosive mixture refers to a mixture of flammable substances in the form of gas, vapour, mist, dust or fibres with air which, under atmospheric conditions (-20°C < temperature < +60°C, 0.8 bar < pressure < 1.1 bar), will propagate combustion over the whole range after ignition.
    1.1.2 "Zone"
    A "zone" refers to all or part of an explosive hazardous location. The classification of "zones" is based on the probability of occurrence of the explosive mixture; according to the frequency and duration of the appearance of the explosive mixture it can be divided into several zones of different hazard levels

    Probability of occurrence of the explosive mixture Gas mixture Dust mixture
    Not likely to occur, or occurs only for a short period (t<10 hours/year Zone 2 Zone 22
    Likely to occur occasionally (10<t<1000 hours/year Zone 1 Zone 21
    Occurs continuously, or for a long period, or frequently (t>1000 hours/year) Zone 0 Zone 20
     

    1.2 The "ATEX 95 (ATEX 94/9/EC) directive" standard
    The "ATEX 95 (ATEX 94/9/EC) directive" standard came into effect in March 1996 and became mandatory from 1 July 2003. The popularization and use of this standard has improved the safety performance of instruments and protected the safety and health of on-site workers; it has made the certification procedures of various countries consistent; and it has facilitated the free trade of instruments between countries. The ATEX 95 standard matches the ATEX 137 standard and defines the protection methods corresponding to the "zones".
    Listed below is a safety marking of a unit complying with the ATEX 95 safety standard:
    ATEX II 2 (1) G EEx d [ia] IIC T6
    This indicates that the instrument complies with the ATEX standard and can be used for gas explosion protection in zone 1 of general industries; the explosion protection type is EEx d [ia], the flammable gas category is IIC and the temperature class is T6. The following will introduce several concepts separately: explosive atmosphere category/level, flammable gas category, temperature class and explosion protection type.
    1.2.1 Explosive atmosphere category/level
    The ATEX 95 standard classifies categories according to the explosive atmosphere in which the instrument is used, and the categories can be further divided into levels
    Mining industry

    Category I (Group I)

    Level M1 (Category M1) Level M2 (Category M2)
    Operation in hazardous atmospheres (IM1) Shutdown in hazardous atmospheres (IM2)
    General industries

    Category II (Group II)

    Level 1 (Category 1) Level 2 (Category 2) Level 3 (Category 3)
    Gas (Gas-Ex) Zone 0 (II 1G) Zone 1 (II 2G)  Zone 2 (II 3G)
    Dust (Dust-Ex) Zone 20 (II 1D) Zone 21 (II 2D) Zone 22 (II 3D)
    Certificate granted by a qualified third party Certificate granted by the manufacturer
     

    1.2.2 Flammable gas category
    In an explosive atmosphere, ignition sources that can cause an explosion include hot surfaces, flames, mechanical friction sparks, electrostatic sparks, lightning, electromagnetic radiation, ultrasonic radiation, etc. The ATEX95 standard classifies flammable gases or vapours according to the ignition temperature of hot surfaces and the ignition energy of electric sparks
    Group Minimum ignition energy (intrinsic safety) Maximum experimental safe gap (flameproof)
    I Mining industry Methane
    II General industries A >160μJ (e.g. propane, etc.) 0.4mm
    B >60μJ (e.g. ethylene, etc.) 0.2mm
    C >20μJ (e.g. hydrogen/acetylene, etc.) 0.15mm

     

     1.2.3 Temperature class
    The temperature class is a class classified according to the maximum surface temperature of the instrument. Method of temperature class classification

    Temperature class  Maximum surface temperature Remarks
    T1 450°C Ambient temperature: 40°C
    T2 300°C
    T3 200°C
    T4 135°C
    T5 100°C
    T6 85°C

    In table 4, the maximum surface temperature refers to the highest temperature of any part of any surface exposed to the explosive mixture at which the instrument, when operating under the most unfavourable conditions within the permitted range, cannot cause ignition of the explosive mixture surrounding the instrument.
    In order to prevent static electricity accumulated on non-conductive (RS > 1 GΩ) plastic surfaces from possibly igniting the explosive mixture, the ATEX95 standard also specifies the conditions that non-conductive surfaces must meet

    Exposed plastic enclosure area Maximum diameter of rods and cables Maximum thickness of plastic lining on metal surfaces
    Group Zone 0 Zone 1 Zone 0 Zone 1 Zone 0+1
    IIA 50cm2 100cm2 3mm 30mm 2mm
    IIB 25cm2 100cm2 3mm 30mm 2mm
    IIC 4cm2 20cm2 1mm 20mm 0.2mm

    1.2.4 Explosion protection type
    Explosion protection type refers to the various specific measures taken for the instrument to prevent ignition of the surrounding explosive mixture. The explosion protection types classified by the "ATEX 95 (ATEX 94/9/EC) directive" standard include: intrinsic safety EEx ia/ib, flameproof Ex d, increased safety Ex e, filling Ex q (the electronic part immersed in quartz powder), pressurization Ex p (air or inert gas pressurizing the electronic part), oil immersion Ex o (the electronic part immersed in oil), encapsulation Ex m (the electronic part encapsulated in epoxy resin), dust flameproof Ex tD, dust intrinsic safety Ex iD, dust encapsulation Ex mD, etc.

    In summary, these explosion protection types mainly take safety protection measures in the following 3 aspects:
    (1) avoiding the generation and propagation of explosive atmospheres;
    (2) avoiding the appearance of potential ignition sources in explosive hazardous locations;
    (3) reducing the harm caused by explosions.

    The following will mainly introduce 4 explosion protection types: intrinsic safety EEx ia/ib, flameproof Ex d, increased safety Ex e and flameproof increased safety Ex de.

    1.2.4.1 Intrinsic safety EEx ia/ib (intrinsical safety EEx ia/ib)

    A circuit in which neither the electric sparks nor the thermal effects produced under normal operation or under the specified fault conditions can ignite the specified explosive gas under the test conditions specified in the relevant standards is called an intrinsically safe circuit; an instrument all of whose circuits are intrinsically safe circuits is called an intrinsically safe instrument.

    An intrinsically safe instrument must be connected in an intrinsically safe circuit. The intrinsic safety of the whole circuit is achieved through the following 3 aspects:
    (1) intrinsically safe instruments;
    (2) energy limitation of the power supply, such as a safety barrier (making the current and voltage indexes of the power supply lower than those of the intrinsically safe instrument);
    (3) low capacitance and inductance of the whole circuit to prevent energy storage.

    Intrinsically safe instruments are mainly used in zone 1 and zone 0. By using an intrinsically safe circuit the whole circuit is protected and no additional mechanical protection is needed. In addition, intrinsically safe instruments can be opened on site while energized.

    According to the EN 50020 standard, the complete solution for EEx ia and EEx ib is shown in the figure below



    1.2.4.2 Flameproof Ex d (flame proof Ex d)

    A protective enclosure built to contain parts capable of igniting explosive gas is called a flameproof enclosure. A flameproof enclosure can withstand the pressure generated by an internal explosion of the explosive mixture and prevent the internal explosion from propagating to the explosive gas surrounding the enclosure. An instrument with a flameproof enclosure is called a flameproof instrument. A flameproof instrument achieves flameproofing through flameproof cable glands, a conduit system or increased-safety terminal blocks.
     
    1.2.4.3 Increased safety Ex e (increased safety Ex e )

     Increased safety is specially designed for use in explosive gas atmospheres: under normal operating conditions it will not produce arcs, sparks or high temperatures that could ignite the explosive gas, and measures are taken in the structure of the instrument to increase the degree of safety so as to avoid these phenomena under normal operating conditions or approved overload conditions. Increased-safety instruments achieve explosion protection through increased-safety cable glands and fail-safe devices.

    1.2.4.4 Flameproof increased safety Ex de
    If additional safety measures (such as flameproof cable glands) are provided between the electronic chamber and the terminal chamber of a flameproof instrument, such an instrument is called a flameproof increased-safety instrument (Ex de).  
    1.2.4.5 Encapsulated flameproof type
    Explosion-proof electrical equipment for explosive gas (liquid) atmospheres - encapsulated type "Exm I/IIT4" Explosion-proof electrical equipment for explosive gas (liquid) atmospheres - flameproof type "dIIBT3/T4" Explosion-proof electrical equipment for explosive gas (liquid) atmospheres - flameproof type "dIICT4/T5" The flameproof protection type encloses all the parts of the equipment that may ignite the explosive gas mixture in an enclosure; the enclosure can withstand an internal explosion of the combustible mixture that penetrates into the interior of the enclosure through any joint surface or structural gap of the enclosure without being damaged, and will not cause ignition of the external explosive atmosphere formed by one or more gases or vapours. All parts that may produce sparks, arcs and dangerous temperatures are placed in the flameproof enclosure, which separates the internal space of the equipment from the surrounding environment. The flameproof enclosure has gaps; due to the breathing action of the electrical equipment and gas permeation, an explosive gas mixture may exist inside. When it explodes, the enclosure can withstand the explosion pressure generated without being damaged, and at the same time the structural gaps of the enclosure can cool the flame, reduce the flame propagation speed or terminate the acceleration chain, so that the flame or dangerous flame products cannot pass through the flameproof gap to ignite the external explosive atmosphere, thereby achieving the purpose of flameproofing. Friendly reminder: it must pass the relevant national explosion-proof inspection and obtain the corresponding explosion-proof certificate before it can be selected!

CONTACT US