Your Position: Home > Technical Data > Certifications

Example
Example
Example
API-6A
API-Q1
Example
Application of SIL
Example
Example
Example
Example | Probability of occurrence of the explosive mixture | Gas mixture | Dust mixture |
| Not likely to occur, or occurs only for a short period (t<10 hours/year | Zone 2 | Zone 22 |
| Likely to occur occasionally (10<t<1000 hours/year | Zone 1 | Zone 21 |
| Occurs continuously, or for a long period, or frequently (t>1000 hours/year) | Zone 0 | Zone 20 |
| Mining industry | Category I (Group I) |
||
| Level M1 (Category M1) | Level M2 (Category M2) | ||
| Operation in hazardous atmospheres (IM1) | Shutdown in hazardous atmospheres (IM2) | ||
| General industries | Category II (Group II) |
||
| Level 1 (Category 1) | Level 2 (Category 2) | Level 3 (Category 3) | |
| Gas (Gas-Ex) | Zone 0 (II 1G) | Zone 1 (II 2G) | Zone 2 (II 3G) |
| Dust (Dust-Ex) | Zone 20 (II 1D) | Zone 21 (II 2D) | Zone 22 (II 3D) |
| Certificate granted by a qualified third party | Certificate granted by the manufacturer | ||
| Group | Minimum ignition energy (intrinsic safety) | Maximum experimental safe gap (flameproof) | |
| I Mining industry | Methane | ||
| II General industries | A | >160μJ (e.g. propane, etc.) | 0.4mm |
| B | >60μJ (e.g. ethylene, etc.) | 0.2mm | |
| C | >20μJ (e.g. hydrogen/acetylene, etc.) | 0.15mm | |
1.2.3 Temperature class
The temperature class is a class classified according to the maximum surface temperature of the instrument. Method of temperature class classification
| Temperature class | Maximum surface temperature | Remarks |
| T1 | 450°C | Ambient temperature: 40°C |
| T2 | 300°C | |
| T3 | 200°C | |
| T4 | 135°C | |
| T5 | 100°C | |
| T6 | 85°C |
In table 4, the maximum surface temperature refers to the highest temperature of any part of any surface exposed to the explosive mixture at which the instrument, when operating under the most unfavourable conditions within the permitted range, cannot cause ignition of the explosive mixture surrounding the instrument.
In order to prevent static electricity accumulated on non-conductive (RS > 1 GΩ) plastic surfaces from possibly igniting the explosive mixture, the ATEX95 standard also specifies the conditions that non-conductive surfaces must meet
| Exposed plastic enclosure area | Maximum diameter of rods and cables | Maximum thickness of plastic lining on metal surfaces | |||
| Group | Zone 0 | Zone 1 | Zone 0 | Zone 1 | Zone 0+1 |
| IIA | 50cm2 | 100cm2 | 3mm | 30mm | 2mm |
| IIB | 25cm2 | 100cm2 | 3mm | 30mm | 2mm |
| IIC | 4cm2 | 20cm2 | 1mm | 20mm | 0.2mm |
1.2.4 Explosion protection type
Explosion protection type refers to the various specific measures taken for the instrument to prevent ignition of the surrounding explosive mixture. The explosion protection types classified by the "ATEX 95 (ATEX 94/9/EC) directive" standard include: intrinsic safety EEx ia/ib, flameproof Ex d, increased safety Ex e, filling Ex q (the electronic part immersed in quartz powder), pressurization Ex p (air or inert gas pressurizing the electronic part), oil immersion Ex o (the electronic part immersed in oil), encapsulation Ex m (the electronic part encapsulated in epoxy resin), dust flameproof Ex tD, dust intrinsic safety Ex iD, dust encapsulation Ex mD, etc.
In summary, these explosion protection types mainly take safety protection measures in the following 3 aspects:
(1) avoiding the generation and propagation of explosive atmospheres;
(2) avoiding the appearance of potential ignition sources in explosive hazardous locations;
(3) reducing the harm caused by explosions.
The following will mainly introduce 4 explosion protection types: intrinsic safety EEx ia/ib, flameproof Ex d, increased safety Ex e and flameproof increased safety Ex de.
1.2.4.1 Intrinsic safety EEx ia/ib (intrinsical safety EEx ia/ib)
A circuit in which neither the electric sparks nor the thermal effects produced under normal operation or under the specified fault conditions can ignite the specified explosive gas under the test conditions specified in the relevant standards is called an intrinsically safe circuit; an instrument all of whose circuits are intrinsically safe circuits is called an intrinsically safe instrument.
An intrinsically safe instrument must be connected in an intrinsically safe circuit. The intrinsic safety of the whole circuit is achieved through the following 3 aspects:
(1) intrinsically safe instruments;
(2) energy limitation of the power supply, such as a safety barrier (making the current and voltage indexes of the power supply lower than those of the intrinsically safe instrument);
(3) low capacitance and inductance of the whole circuit to prevent energy storage.
Intrinsically safe instruments are mainly used in zone 1 and zone 0. By using an intrinsically safe circuit the whole circuit is protected and no additional mechanical protection is needed. In addition, intrinsically safe instruments can be opened on site while energized.
According to the EN 50020 standard, the complete solution for EEx ia and EEx ib is shown in the figure below
![]()
1.2.4.2 Flameproof Ex d (flame proof Ex d)
A protective enclosure built to contain parts capable of igniting explosive gas is called a flameproof enclosure. A flameproof enclosure can withstand the pressure generated by an internal explosion of the explosive mixture and prevent the internal explosion from propagating to the explosive gas surrounding the enclosure. An instrument with a flameproof enclosure is called a flameproof instrument. A flameproof instrument achieves flameproofing through flameproof cable glands, a conduit system or increased-safety terminal blocks.
1.2.4.3 Increased safety Ex e (increased safety Ex e )
Increased safety is specially designed for use in explosive gas atmospheres: under normal operating conditions it will not produce arcs, sparks or high temperatures that could ignite the explosive gas, and measures are taken in the structure of the instrument to increase the degree of safety so as to avoid these phenomena under normal operating conditions or approved overload conditions. Increased-safety instruments achieve explosion protection through increased-safety cable glands and fail-safe devices.
1.2.4.4 Flameproof increased safety Ex de
If additional safety measures (such as flameproof cable glands) are provided between the electronic chamber and the terminal chamber of a flameproof instrument, such an instrument is called a flameproof increased-safety instrument (Ex de).
1.2.4.5 Encapsulated flameproof type
Explosion-proof electrical equipment for explosive gas (liquid) atmospheres - encapsulated type "Exm I/IIT4" Explosion-proof electrical equipment for explosive gas (liquid) atmospheres - flameproof type "dIIBT3/T4" Explosion-proof electrical equipment for explosive gas (liquid) atmospheres - flameproof type "dIICT4/T5" The flameproof protection type encloses all the parts of the equipment that may ignite the explosive gas mixture in an enclosure; the enclosure can withstand an internal explosion of the combustible mixture that penetrates into the interior of the enclosure through any joint surface or structural gap of the enclosure without being damaged, and will not cause ignition of the external explosive atmosphere formed by one or more gases or vapours. All parts that may produce sparks, arcs and dangerous temperatures are placed in the flameproof enclosure, which separates the internal space of the equipment from the surrounding environment. The flameproof enclosure has gaps; due to the breathing action of the electrical equipment and gas permeation, an explosive gas mixture may exist inside. When it explodes, the enclosure can withstand the explosion pressure generated without being damaged, and at the same time the structural gaps of the enclosure can cool the flame, reduce the flame propagation speed or terminate the acceleration chain, so that the flame or dangerous flame products cannot pass through the flameproof gap to ignite the external explosive atmosphere, thereby achieving the purpose of flameproofing. Friendly reminder: it must pass the relevant national explosion-proof inspection and obtain the corresponding explosion-proof certificate before it can be selected!