Fossil-Fuel Power Plant
Classified by total installed capacity:
Small-capacity power plant (total installed capacity < 100 MW)
Medium-capacity power plant (total installed capacity 100 - 250 MW)
Large and medium-capacity power plant (total installed capacity 250 - 600 MW)
Large-capacity power plant (total installed capacity 600 - 1000 MW)
Extra-large-capacity power plant (total installed capacity > 1000 MW)
Classified by steam pressure and temperature:
Medium- and low-pressure power plant (steam pressure 3.92 MPa, temperature 450 degrees, unit output < 25 MW)
High-pressure power plant (steam pressure 9.9 MPa, temperature 540 degrees, unit output < 100 MW)
Ultra-high-pressure power plant (steam pressure 13.83 MPa, temperature 540 degrees, unit output < 20 MW)
Subcritical-pressure power plant (steam pressure 16.77 MPa, temperature 540 degrees, unit output 300 -1000 MW)
Supercritical-pressure power plant (steam pressure > 22.11 MPa, temperature 550 degrees, unit output > 600 MW)
Ultra-supercritical-pressure power plant (steam pressure >33.5 MPa, 610℃/630℃, unit output > 600 MW)
Flow diagram of a fossil-fuel power plant
Combustion system
Steam-water system
Nuclear Power Plant
Valves for nuclear power plants are an essential and important part of the safe operation of nuclear power plants. Nuclear power valves include the valves used in the nuclear island (NI), conventional island (CI) and balance of plant (BOP) systems.
Because of the high particularity, high safety and high reliability required by nuclear power plants, the design and manufacture of nuclear power valve products involve more testing requirements and stricter standards than conventional valves.
According to the safety class they are divided into nuclear safety class I, class II, class III and non-nuclear class, among which nuclear safety class I has the highest requirements and requires nuclear-grade certification.
A nuclear power plant with two 1,000 MW units has about 30,000 valves of various types. The investment cost of nuclear power valves accounts for about 2% of the total investment in nuclear power construction
System: API1000 nuclear island NI, number of valves: 7500, proportion: 35.5%
Conventional island CI, number of valves: 11200, proportion: 50.9%
BOP, number of valves: 3300, proportion: 13.6%
System: CPR1000 nuclear island NI, number of valves: 12700, proportion: 43.5%
Conventional island CI, number of valves: 12800, proportion: 44.5%
BOP, number of valves: 3400, proportion: 11.7%
System: Hualong One nuclear island NI, number of valves: 12000, proportion: 42.8%
Conventional island CI, number of valves: 13000, proportion: 46.4%
BOP, number of valves: 3000, proportion: 10.7%
Power Plant Valves
● Condenser system
1. Condenser recirculation control valve
Like most centrifugal pumps, condensate pumps need a minimum flow to avoid overheating and to protect the pump from cavitation damage. Therefore a recirculation loop is added from the pump outlet back to the condenser; the fluid temperature in this loop is 38℃-66℃ and the pressure is 400 Psi to 600 Psi.
The condenser recirculation valve must be able to absorb the entire pressure drop. Such a high pressure drop would cause cavitation in an ordinary valve.
2. Deaerator level control valve
The function of this valve is to ensure the level of the deaerator; it controls the flow of water from the condenser to the deaerator. The operating condition of this valve changes very directly with load: at the very beginning of startup the pump load is small and the valve inlet pressure is high while the outlet pressure is low, because the pressure in the deaerator has not yet been established. In this case cavitation must be avoided and the flow is very small; when the plant load increases, a large flow is required, and the condensate pump no longer maintains the same pump head at the larger flow.
This causes the valve inlet pressure to decrease.
At the same time, the pressure of the line against the deaerator is building up, and it acts back on the valve. Maintaining a large flow under a low pressure drop requires a valve with high flow capacity to reduce the resistance acting on the trim. Control requirements: provide flow to maintain the normal water level of the deaerator, and raise the water temperature by adding steam so as to eliminate the gases dissolved in the water. Operating conditions: small flow and large pressure difference at the startup stage, large flow and small pressure difference under normal conditions, similar to a feedwater valve. Valve requirements: effective anti-cavitation at low flow,
● Boiler feedwater system
Operating condition requirements: during boiler startup the pressure difference across the valve can reach 100-300 kg/cm2 with a small flow; in normal operation the pressure difference is small and the flow is large, and the flow turndown ratio can be 75:1-100:1. It should be noted that hydrazine is usually added to the feedwater to eliminate dissolved oxygen, and it reacts adversely with SATELLITE 6 alloy or other similar alloys, so it is best not to treat the trim by the 316 + STELLITE hardfacing method; 416 stainless steel material may be selected directly
1. Boiler feedwater pump recirculation control valve (also called minimum flow control valve)
During startup and shutdown, the feedwater pump needs to maintain a minimum flow to avoid damage. In addition, when the boiler feedwater quantity exceeds the required amount, the excess is returned directly to the feedwater tank through the open recirculation valve. This enables the boiler feedwater pump to start and operate safely and prevents pump damage caused by too low a flow, increased temperature rise and severe water cavitation
The pressure drop reaches 160-350 kg/cm2, making it the valve bearing the largest pressure difference in the power plant system; the flow is generally 30% of the normal flow.
Usually there is a very high pressure difference between the pump outlet and the feedwater tank, and this pressure difference is reduced by a multi-stage pressure-reducing minimum flow valve. According to this requirement, the valve needs to be able to work both in on/off mode and in continuous control mode.
The trim adopts a balanced piston form. Anti-clogging structure; pressure reduction is accomplished through a labyrinth or cascade pressure-reducing or reverse convection cage to avoid cavitation, and the number of pressure-reducing stages is selected according to the different pressure differences; the sealing class must be class V. The valve works continuously during pump startup and shutdown, and closes after the pump starts normally, so it is usually fail-open.
2. Main feedwater control valve
If the feedwater pump does not have speed control, the feedwater control valve serves as the control valve at 100% load. The feedwater control valve is often used during boiler load startup (with or without a variable-speed pump).
. Stable, well-controlled tracking performance
. Sleeve and plug specially designed for the feedwater valve to achieve tightness and high durability
. At small opening control, standard labyrinth trim and multi-hole cage trim will suppress cavitation
In this valve there are two opposing functions
. At full load, the maximum flow passes through the valve with the minimum pressure drop to achieve the expected optimum efficiency
. During boiler startup, high pressure difference and small flow. To satisfy the above two functions, this control valve needs to have a very large rangeability; the valve is equivalent to the function of two valves: a 30% startup valve (bypass
) usually adopts labyrinth trim, while a multi-hole cage type is selected at full load, class V sealing.
3. Boiler feedwater startup valve
Many power plants use a startup valve and a main valve to accomplish the above functions. The startup valve must meet small flow and cavitation resistance, while the main valve must meet the conditions of large flow and small pressure difference; labyrinth trim can enable the same valve to meet the requirements of the whole range
The requirements for this valve are
. Large rangeability and cavitation resistance at small flow
. Low flow resistance at maximum flow
. Leakage class meeting class V shut-off
. Fail-close
The operating conditions of the boiler feedwater startup valve are broadly similar to those of the boiler feedwater pump recirculation valve, namely a very high inlet pressure and the full pressure drop; this valve requires anti-cavitation and tight shut-off. Unlike the boiler feedwater pump recirculation valve, this valve does not need to provide anti-cavitation protection while all valves are in operation; therefore a cage valve with a labyrinth plug can satisfy this condition. Usually we recommend a small-bore angle valve structure with labyrinth trim.
4. Desuperheating spray water control valve
To control the temperature well at the final stage of the superheater, a high-efficiency spray water valve is required. Similarly, in the steam desuperheating device it must also be taken into account that the cooling water sometimes needs to be shut off; at that time a very high pressure acts on the components, and a very large pressure drop passes through these valves. Considering such a high pressure drop, a variety of different throttling plugs can be adopted to meet it.
When the pressure exceeds 300 psig, a multi-hole single-stage valve assembly is used; when the pressure exceeds 600 psig, a two-stage pressure-reducing valve assembly is used; when the pressure exceeds 900 psig, a multi-hole three-stage pressure-reducing assembly is used, in the form of labyrinth trim. These multi-stage and labyrinth-trim spray water valves commonly adopt a quickly replaceable seat form, which ensures convenient maintenance under heavy-duty conditions; this structural design allows the seat and plug to be replaced in a very short time
5. Boiler periodic blowdown valve and continuous blowdown valve
High temperature, high pressure difference, anti-cavitation; angle valve preferred.
● Main steam system
The main steam system includes the steam circulation components from the boiler outlet to the condenser. It covers the path from the superheater to the high-pressure steam turbine, then through the reheater to the low-pressure steam turbine, and finally the complete exhaustion of the steam's energy and its return to the condenser to start a new cycle.
5 important typical valve applications are used in this main steam system, including the spray water control valves for superheater and reheater desuperheating, the high-pressure and low-pressure steam turbine bypass valves, and the sootblowing control valve
All of these involve various complex operating conditions, including high pressure, high temperature, cavitation, noise, the type of boiler, the form of the storage tank, and whether it is once-through; all of these have a very great influence on the control valve.
A once-through supercritical boiler is usually a relatively large unit and requires relatively large valves; it also operates at a higher main steam pressure. In addition to the valves mentioned, some special valves are used on once-through boilers.
1. High-pressure steam turbine bypass valve
The high-pressure steam turbine bypass valve is in the form of a high-pressure angle valve, and the pressure is reduced through the trim. The high-pressure steam turbine bypass system provides an alternate flow path for high-temperature, high-pressure steam, bypassing the turbine and flowing into the reheat section.
When the turbine is abnormal or during startup operation, this bypass system can ensure stable operation of the entire boiler; at this time the steam flows through the high-pressure bypass valve, and the outlet temperature of the bypass valve is made slightly higher than the normal high-pressure steam turbine outlet temperature by the spray water control valve.
This control system must be able to meet fast valve opening and continuous feedback regulation according to the set temperature and pressure; the valve opening time is generally not more than 5 seconds. When this bypass valve is working, it must be able to provide the same pressure drop and cooling function to protect the downstream boiler reheater section from damage, and in addition it must be able to unload the turbine quickly without interrupting the boiler.
A bypass is generally a device that discharges the main steam directly into the condenser through desuperheating and pressure reduction without passing through the turbine.
The high- and low-pressure bypass systems have three functions: startup, overflow and safety.
The structure is similar to an integrated desuperheating and pressure-reducing device, with higher pressure and higher temperature, and higher requirements on materials and valve operating reliability; the valve is generally normally closed, requires a sealing class of class V or above, and at the same time needs to open quickly within 3-5S.
Control requirements: adjust high-temperature, high-pressure steam to steam at a certain temperature and pressure; provide a bypass channel for the turbine so that the boiler can operate independently of the turbine. Operating conditions: desuperheating and pressure reduction of high-temperature, high-pressure steam. Valve requirements: thermal shock resistance, noise reduction, rapid response.
2. Low-pressure steam turbine bypass valve
The low-pressure bypass system provides a bypass channel for the low-pressure steam turbine and controls the regulation of steam pressure and temperature, regardless of whether the high-pressure bypass system is in operation.
The low-pressure bypass valve receives the steam from the boiler reheater and regulates it so that it can be accepted by the condenser. The high temperature and high pressure are brought down through throttling in the valve and a large flow of desuperheating spray water. The temperature control requirement is not too strict; the purpose is only to protect the condenser. This protection is achieved by spray water and fast shut-off.
The application of the low-pressure bypass or condenser usually has to take into account the low-pressure bypass process conditions: including high pressure, high temperature, noise, valve tightness and desuperheating requirements
3. Sootblowing control valve
A good control valve is needed for sootblowing pressure control. In a sootblowing cycle the flow varies greatly, so the valve is required to have a large flow rangeability,
When the sootblowing system is switched on and off, this control valve must respond quickly to avoid pressure surges and keep the pipeline safe,
Because the temperature and pressure are very high, this application requires a very high pressure class for the valve. In addition, useful steam must not be wasted, so tight shut-off is required, which makes the requirements relatively severe. This sootblowing valve usually operates many times within a day, especially when an isolation valve isolates it from the steam line. The service temperature of this valve must be able to cover the entire service temperature range. Besides the influence of temperature, the high pressure drop will cause strong noise and will damage the plug and cause vibration. Therefore the plug designed for this application must have very high performance. Taking all the above into consideration, high noise and frequent operation are important factors causing problems, so we adopt a labyrinth plug to meet this condition: the valve reduces the flow velocity, and it also has a very wide rangeability; the trim adopts an unbalanced design and a high-torque actuator to ensure tight shut-off.
4. Auxiliary steam control valve
The auxiliary steam for different equipment is obtained by reducing the pressure of the main steam. Because the pressure difference is high, vibration and noise will be generated. This type of control valve must avoid the generation of vibration and noise, and in addition requires a relatively wide flow regulation range; the structure and material must be able to adapt to the requirements of high-temperature, high-pressure steam.
5. Deaerator pegging steam control valve
The deaerator is similar to a heater (in which steam and feedwater are mixed) and is additionally specially designed to remove the non-condensable gases in the feedwater,
these gases include oxygen and carbon dioxide, which will damage and corrode the pipes and the straight tubes of the boiler. Usually hot steam is mixed with the feedwater in the deaerator to bring the temperature to the saturation temperature, so that the non-condensable gases can be removed,
for a drum boiler the steam is extracted from the auxiliary line of the main steam pipe; for a once-through boiler the steam is extracted from the flash tank or the end of the high-pressure heater, so its pressure is somewhat lower than that of a drum boiler
, the steam pressure is usually higher than the required pressure, so it must be reduced; this valve must consider the noise problem. The requirements for the deaerator pegging steam valve are relatively severe because the noise is relatively high, and special silencing equipment will be applied.
6. Turbine gland seal pressure control valve
7. Steam trap
There are ball valve type and globe valve type; the body is generally forged, with materials such as A105, F22 and F91; the size is generally 1-3", the rating 150-4500#, and the actuator is manual or electric.
● Heater drain system
In a typical power plant there are two sets of feedwater heaters: the low-pressure heaters heat the water coming from the condensate pump so that it enters the deaerator close to saturation; the other set is called the high-pressure heaters,
which heat the deaerated water coming from the feedwater pump, so that high-pressure, nearly saturated deaerated water enters the boiler. The two systems work on the same principle; what differs is the heating medium,
in the low-pressure heaters the medium commonly used is the steam exhausted from the low-pressure steam turbine, while the high-pressure heaters use superheated steam from the reheat section. A feedwater heater is a shell-and-tube heat exchanger. The steam enters, is cooled and condensed into liquid
and in this process the heat is transferred to the water. The condensate level in the heater must be controlled efficiently, so the drain system is quite sophisticated. In both heater systems,
the drain will cause a vacuum in the condenser; the problem is that after the condensate is discharged to the condenser it loses pressure and flashing occurs. The flashed fluid will damage the control valve and the piping
, when selecting this valve the key point is low flow resistance, reducing the flow velocity as far as possible to minimize the damage of flashing to the valve. Material selection is likewise very critical
1. High-pressure heater drain control valve
For the high-pressure heater drain system, the control valve is required to ensure a stable pressure; it is first recommended to select A217-WC9 (A182-F22) or A217-C5 (A182-F5) alloy steel, with a carbide-treated plug, and the material must resist erosion and impact. When the pressure class is as high as ANSI 1500LB, an angle-type structure is recommended, which can avoid erosion. A labyrinth-type plug can reduce the flow velocity as much as possible.
Control requirements: control the position of the condensate in the heater and discharge the condensate in time, i.e. discharge at high level and drain at normal level. Operating conditions: the medium is saturated water; the pressure difference across the control valves between heaters is generally 6-30 kg/cm2; the drain valve of the last stage is connected directly to the condenser or the deaerator. Valve requirements: resistance to flashing erosion, class V or VI sealing, the valve is usually fail-open.
2. Low-pressure heater drain control valve
For the low-pressure heater drain system, if a straight-through valve is selected, a WC9 material valve with a heat-treated plug is a good choice.
3. Fuel oil and gas control valve
Fuel oil: seal leakage is not permitted; fast response is required in emergency situations
4. High-pressure heater three-way valve
This type of valve is designed to provide a bypass for the high-pressure feedwater when a fault occurs in the high-pressure heater internal piping, weld joints or drain system, or when the high-pressure heater needs maintenance.