Types of check valve
A check valve, also called a one-way valve or non-return valve, is a valve whose closing element opens or closes by itself under the flow and force of the medium in order to prevent backflow. It belongs to the class of automatic valves and is mainly used in pipelines where the medium flows in one direction, allowing flow in one direction only so as to prevent accidents.

Classification of check valves
Lift check valve: a check valve whose disc slides along the vertical centre line of the body. Lift check valves can only be installed in horizontal pipelines; in high-pressure small-diameter check valves a ball may be used as the disc. The body shape of a lift check valve is the same as that of a globe valve (it can be used interchangeably with a globe valve), so its fluid resistance coefficient is relatively large.



Swing check valve: a check valve whose disc rotates about a pin outside the seat; the swing check valve is relatively widely used.



Butterfly check valve (double-disc or single-disc check valve)



In-line check valve (axial-flow type)
A valve whose disc slides along the centre line of the body. The in-line check valve is a newly emerging valve: it is small in size, relatively light in weight and easy to manufacture, and represents one of the development directions for check valves. Its fluid resistance coefficient, however, is slightly larger than that of a swing check valve.


Selection and installation of check valves
    Selection of check valves
    To prevent reverse flow of the medium, check valves should be installed on equipment, installations and pipelines;
    Check valves are generally suitable for clean media and should not be used for media containing solid particles or of relatively high viscosity;
    On horizontal pipelines of nominal diameter 50 mm, vertical lift check valves should generally be selected;
    Straight-through lift check valves can be installed in both horizontal and vertical pipelines;
    For pump suction lines a check valve should preferably be used; a foot valve is generally installed only on the vertical pipe at the pump suction, with the medium flowing from bottom to top;
    Lift check valves seal better than swing check valves but have greater fluid resistance; horizontal lift check valves should be installed in horizontal pipelines and vertical ones in vertical pipelines;
    The installation position of a swing check valve is unrestricted; it can be installed in horizontal, vertical or inclined lines. If it is installed in a vertical pipe, the medium must flow from bottom to top;
    Swing check valves should not be made in small sizes; they can be made for very high working pressures, with PN up to 42 MPa, and for very large DN, up to 2000 mm and above. Depending on the material of the shell and of the sealing parts they can be used with any working medium and over any working temperature range: water, steam, gas, corrosive media, oil products, pharmaceuticals, etc. The working temperature range of the medium is between -196 and 800 °C
    The installation position of a butterfly check valve is unrestricted; it can be installed in horizontal pipelines, or in vertical or inclined lines;
    Diaphragm check valves are suitable for pipelines where water hammer is likely; the diaphragm damps the water hammer generated by reverse flow very well. They are generally used in low-pressure, ambient-temperature pipelines and are especially suitable for water supply pipelines. The usual working temperature of the medium is between -12 and 120 °C and the working pressure is below 1.6 MPa, but diaphragm check valves can be made in relatively large sizes, with DN up to 2000 mm and above;
    Ball check valves are suitable for medium- and low-pressure pipelines and can be made in large sizes; the body material can be stainless steel and the hollow ball of the sealing element can be coated with PTFE engineering plastic, so they can also be used in pipelines carrying ordinary corrosive media. The working temperature is between -101 and 150 °C, the nominal pressure is ≤ 4.0 MPa and the nominal diameter range is 200-1200;
    When selecting a check valve for an incompressible fluid, the required closing speed must first be assessed, and the second step is to choose the type of check valve that can meet that closing speed;
    Check valves for compressible fluids can be selected by a method similar to that used for incompressible fluids. If the range of medium flow is very wide, a retarding device may be used on the check valve for compressible fluids; if the medium flow stops and starts rapidly and continuously, as at the outlet of a compressor, a lift check valve is used;
    The size of the check valve must be determined; the valve supplier must provide the data for the selected size, so that the valve size at which the valve is fully open at a given flow velocity can be found;
    For check valves with a minimum pressure loss requirement, the pressure loss must be calculated carefully.


    Points to note when installing check valves
    1. Do not let the check valve carry weight in the pipeline; large check valves should be supported independently so that they are not affected by the forces generated by the piping system.
    2. When installing, make sure that the direction of medium flow agrees with the direction of the arrow marked on the valve body.
    3. Lift check valves with a vertical disc should be installed in vertical pipelines.
    4. Lift check valves with a horizontal disc should be installed in horizontal pipelines.

Selection and installation of pump discharge check valves
    Selection of pump discharge check valves
    In the usual pump station project, the following principles should be followed when selecting a pump discharge check valve;
    For pump discharge lines of smaller diameter, i.e. DN less than 50 mm, lift check valves should be selected.
    For pump discharge lines of DN 50 mm and above, swing check valves should be selected.
    Swing check valves can be installed horizontally or vertically. The disc of a swing check valve rotates about a pivot, and its fluid resistance is generally lower than that of a lift check valve; it is suitable for larger sizes, its installation position is unrestricted, and it is usually installed in a horizontal line; it is suitable for larger sizes. By number of discs it is divided into single-disc, double-disc and multi-disc swing check valves. Single-disc swing check valves are generally used for medium sizes. When a single-disc swing check valve is selected for a large-diameter line, a slow-closing check valve that reduces water hammer pressure is best adopted in order to reduce that pressure. Double-disc swing check valves are suitable for medium and large diameter lines. The wafer double-disc swing check valve is small in construction and light in weight and is a fast-acting check valve; multi-disc swing check valves are suitable for large-diameter lines.
      Installation of pump discharge check valves
    1) Swing check valves are generally installed in horizontal pipelines; check valves of DN 80 mm may also be installed in vertical or upward-inclined pipes.
    2) Straight-through lift check valves should be installed in horizontal pipelines; vertical lift check valves must be installed in vertical pipelines, with the medium flowing from bottom to top.
    3) Because check valves are easily damaged, the check valve should be installed close to the pump outlet, with a shut-off valve (usually a ball valve or gate valve) fitted above it for ease of maintenance.
    4) To make pressure relief easier before dismantling the check valve, if the check valve has no drain valve of its own, a drain valve for pressure relief should be fitted between the check valve and the shut-off valve.
Copyright © 2015 www.ourvalve.com