Structure of the plug valve



A plug valve is simple in structure, switches quickly, has low fluid resistance and operates fast in quarter-turn action. In emergencies such as accidents it can quickly connect or shut off a pipeline. Compared with gate valves and globe valves, its operation is more flexible and its opening and closing are faster.
A plug valve uses a plug with a through-port as its closing element, and the plug turns with the stem to open and close. Small packingless plug valves are also called "cocks". The plug is usually conical (sometimes cylindrical) and forms a sealing pair with the conical bore of the body.
Soft-seated plug valve: soft-seated plug valves are often used in corrosive, highly toxic and other hazardous media under severe conditions where leakage must be strictly prevented, and where the valve material will not contaminate the medium. The body material can be carbon steel, alloy steel or stainless steel according to the working medium.
Self-lubricating bushes of F4, F46, PVDF, PP, PO, PE and similar materials can be used according to the service temperature and working medium; lubrication is good, the friction coefficient of the sealing pair stays small throughout operation, the plug turns freely and the service life is long. The inlet and outlet ports of the body are designed with double-groove sealing rings; as the plug rotates the sealing specific pressure of the sealing pair changes gradually until, at the fully open or fully closed position, sufficient sealing specific pressure is built up and the sealing pair achieves zero leakage. The double-groove sealing ring both holds the bush firmly in the body without displacement and absorbs the slight deformation of the bush caused by temperature differences; at the same time it produces a strong rubbing action between bush and plug that has a self-cleaning effect, increasing the service life of the sealing faces. The unique reverse-lip seal design at the top of the plug, in which a soft-sealing diaphragm and a metal diaphragm are combined with adjusting shims, both adjusts the sealing specific pressure between the sealing faces so that the plug turns freely and guarantees sealing at the inlet and outlet ends and at the centre flange connection. It is suitable for highly erosive gas-solid and liquid-solid media, for example in PVC, urea, phthalic anhydride and caustic soda plants, or for media with strict external leakage requirements such as HF and phosgene. The medium can flow in both directions, the installation direction is unrestricted, and in-line maintenance is possible, which makes use more convenient. The unique design prevents static electricity, is fire-safe and safe in use. Oil-lubricated hard-seated plug valve: oil-lubricated hard-seated plug valves can be divided into conventional oil-lubricated plug valves and pressure-balanced plug valves. Special grease is injected from the top of the plug into the gap between the conical bore of the body and the plug to form an oil film that reduces the operating torque and improves sealing and service life. The working pressure can reach 64 MPa, the maximum working temperature 325 degrees and the maximum size 600 mm.
Applications of plug valves
    1. Conventional oil-lubricated plug valve: in the conventional hard-seated plug valve the plug cone is fitted in the upright position. To reduce friction between the sealing faces of body and plug the valve generally adopts a sealing structure in which sealing grease lubricates the seat. High-pressure sealing oil injected through a high-pressure grease nipple forms a high-pressure sealing ring around the plug, i.e. an oil film between the sealing faces of the body and the plug cone that both seals and lubricates, so opening and closing are easy. To reduce the opening and closing torque of the plug valve further the plug diameter is usually reduced, so plug valves generally have a rectangular flow passage; this lowers the operating torque but increases the fluid resistance of the valve. The sealing area of the plug cone is hardfaced with STL alloy or given a surface-hardening treatment to improve the wear and corrosion resistance of the sealing faces and give a long service life. The surface of the plug cone is precision-ground to a mirror finish and lapped against the sealing face of the body, giving a lower opening and closing torque.


    2. Pressure-balanced plug valve: to reduce the torque of the conventional hard-seated plug valve, the pressure-balanced plug valve is often used. Besides the features of the conventional oil-lubricated plug valve, the pressure-balanced plug valve has the following characteristics: its plug cone is fitted in the inverted position, and a check valve is provided above the plug cone. When the valve is closed, because of the difference in cross-sectional area above and below the plug cone, the injected high-pressure sealing oil exerts an upward lifting force on the plug so that the plug and the sealing face of the valve seal better. At the instant the valve opens, the pressure in the lower cavity of the body balances the medium pressure in the pipeline, and the high-pressure sealing oil in the upper cavity exerts a downward thrust on the plug, so that a very small gap appears between the plug cone and the sealing face of the body and the torque needed to turn the plug is effectively reduced. The sealing pair is also protected. Under high-temperature conditions the thermal expansion of the plug is absorbed by its up-and-down movement, avoiding seizing of the sealing pair. Although oil lubrication of the hard-seated plug valve reduces the opening and closing torque to some extent, it may contaminate the medium; the sealing lubricant must therefore be selected for the actual service conditions. Lift plug valve: lift plug valves come in various structural forms and, according to the material of the sealing faces, in soft-seated and hard-seated versions. The basic principle is that when opening, the plug is first lifted and then turned 90 degrees to the fully open position, which reduces friction against the sealing face of the body; when closing, the plug is turned 90 degrees to the closed position and then lowered into contact with the sealing face of the body to seal.


    3. Double-sealing lift plug valve: the double-sealing lift plug valve has a soft-seated construction. The plug is a cylindrical plug made of three plates: the two side plates carry inlaid rubber sealing faces and the middle is a cylindrical wedge plug. When opening the valve the transmission mechanism raises the plug, drawing the two side plates together so that the combined plug separates from the sealing face of the valve, and then turns the plug 90 degrees to the fully open position. When closing the valve the transmission mechanism turns the combined plug 90 degrees to the closed position and then pushes the plug down; after the side plates touch the bottom of the body they stop moving down while the middle wedge plug continues to descend, and by the action of the inclined surfaces it pushes the two side plates towards the inlet and outlet ends, so that the soft sealing faces of the side plates contact the sealing face of the body and are compressed to seal. The double-sealing lift plug valve has double block and bleed functions; a pressure balancing device is fitted to the valve to prevent abnormal pressure rise in the system and to reduce the resistance at the instant of opening and closing. Because the sealing rings are compressed and the metal faces then contact each other, the valve is fire-safe. Maintenance is very convenient: without removing the body from the pipeline, the two side plates can be taken out of the body for replacement by removing the end cover at the bottom of the body. It is therefore widely used for throttling and on-off control of pipeline fluids in the petroleum, natural gas, metallurgical and mining, gas engineering, light and textile, ship and dock, food and environmental water treatment industries, etc.


    4. Hard-seated lift plug valve: both seat sealing faces of the metal hard-seated lift plug valve can seal, so the use of the valve is not restricted by the flow direction of the medium. When the metal hard-seated lift plug valve is closed, pressure can be applied to the seat sealing face through the handwheel and stem, and by increasing the sealing specific pressure the plug valve achieves better sealing performance. The seat sealing face is raised, which makes it easy to clean and prevents crystalline media or solid particles from accumulating on it; it is therefore often used in high-temperature services in chemical plants. There are various constructions of hard-seated lift plug valves, of which two are common. A. Handwheel-and-handle lift plug valve, working principle: the plug rises and the valve opens fully. When closing, the handle is first turned so that the plug rotates 90 degrees to the closed position, and then the transmission handwheel is turned to lower the plug until it seals. Because the plug separates from the seat during opening and closing, operation is very easy and the sealing faces are not easily scored in the process, giving a long service life. However, the driving torque of a handle is small, so the nominal size of such valves is usually not large. The handwheel-and-handle lift plug valve is compact, small in size and low in fluid resistance. B. Mechanical cross-yoke transmission lift plug valve, working principle: when opening the valve the transmission turns the thread of the stem to raise the plug; after the plug has separated from the sealing face of the body the plug is then driven to rotate 90 degrees to the fully open position. When closing, the transmission first turns the plug 90 degrees to the closed position; the plug then stops rotating and the driving force turns the thread to lower the plug into contact with the sealing face of the body to seal. The mechanical cross-yoke transmission can be connected to a cylinder, an electric actuator or a hydraulic system for remote control. The mechanical cross-yoke transmission lift plug valve removes the limitation of insufficient input torque from the drive and allows valves to develop towards larger sizes and higher pressures. Its plug passage matches the pipe diameter, so fluid resistance is low and pigging is convenient. It is increasingly used on long-distance oil and gas pipelines. Three-way and four-way plug valves: three-way and four-way plug valves are suitable for chemical plants where the direction of medium flow has to be changed or the medium distributed. According to the requirements of the service, soft-seated bushes, or soft-seated or hard-seated lift plug valves, can be selected.


General valve



The GENERAL valve, also called the positive-sealing plug valve or lift-stem plug valve, has DBB capability. It is suitable for services requiring tight shut-off over long periods; typical applications are oil depots and tank farms, airport hydrant jet fuel distribution pipelines and metering skids.
Copyright © 2015 www.ourvalve.com