Desuperheating and pressure reducing units
    Desuperheating and pressure reduction of steam involve two physical processes.
    The first is pressure reduction: by controlling the throttling element, the steam loses potential energy during throttling and its pressure is thereby reduced. Its principle is the same as that of a pressure control valve.
    The second is desuperheating: water is injected into the high-temperature steam. After passing through the nozzle the desuperheating water is broken up into small droplets (primary atomisation); in the steam, because the aerodynamic force generated by the steam flow is greater than the surface tension of the water molecules, the droplets are broken up further to form a water mist (secondary atomisation); the mist is suspended and dispersed in the superheated steam, absorbs heat and, after a period of time, evaporates, thereby lowering the steam temperature. This process follows the principle of enthalpy balance.
    The complete desuperheating and pressure reducing system has many components, such as the pressure reducing module, the desuperheating module, the desuperheating water control module, the measurement module, the safety module, the isolation (stop) module, the piping transport module and the connection module, etc. Each module performs a different function, focuses on a different aspect and refers to different data, and together they accomplish the desuperheating and pressure reduction of the steam and deliver high-quality, stable secondary steam.

    General requirements for desuperheating and pressure reducing units:

    1. Ensure that the desuperheating water is fully atomised. The droplets must be uniform and fine; the evaporation time of a droplet is proportional to the square of its diameter.
    2. Ensure thorough mixing of the vapour and liquid phases: make the steam impact the droplets at higher velocity to create turbulence, so that the droplets evaporate quickly and mix thoroughly.
    3. Control the noise of the pressure-reduced steam and control flashing or cavitation in the desuperheating water valve.

Split-type desuperheating and pressure reducing unit
The split type consists of a steam pressure reducing valve + a desuperheating water control valve + a desuperheating water spray nozzle.
Split type: simple structure, convenient maintenance and low cost; suitable for low temperature and low pressure.



Integral desuperheating and pressure reducing unit
In the integral type, steam pressure reduction and desuperheating are completed within a single valve body, and it consists of a desuperheating and pressure reducing valve + a desuperheating water control valve. Integral type: compact structure, high reliability and high control accuracy; suitable for high temperature and high pressure. For high-temperature, high-pressure process parameters (for example above 9.8 MPa) only the integral type can be used, because such parameters place higher demands on the valve material and the body material must be forged, which is usually designed as an angle type; if a straight-through design were used, the valve would have to be large enough that forging would be uneconomical and casting would be the only option. The integral valve body is readily designed as a multi-stage pressure reducing structure, which is extremely difficult to achieve with a split-type pressure reducing valve.